6500B Series
7 models from 20Hz to 5, 10, 15, 20, 30, 50, and 120MHz
Overview
The 6500B series Precision Impedance Analyzers deliver unparalleled precision in component testing, with a frequency range up to 120 MHz. They stand out in the market with a basic measurement accuracy of ±0.05%, making them the premier choice for applications in passive component design, dielectric material characterization, and manufacturing tests. The series is designed to meet the needs of engineers requiring high-frequency component evaluations with exceptional accuracy.
Technical Specification
Measurement Functions
Capacitance (C), Inductance (L), Resistance (R), Reactance (X), Conductance (G), Susceptance (B)
Dissipation Factor (D), Quality Factor (Q), Impedance (Z)
Admittance (Y), Phase Angle (Ø)
Frequency Range
6505B 20Hz to 5MHz
6510B 20Hz to 10MHz
6515B 20Hz to 15MHz
6520B 20Hz to 20MHz
6530B 20Hz to 30MHz
6550B 20Hz to 50MHz
65120B 20Hz to 120MHz
Frequency step size 0.1 mHz
Accuracy of set frequency ±0.005"%
AC Drive Level
5mV to 1Vrms (varies with frequency)
100µA to 20mArms (varies with frequency)
Measurement Speeds
4 speeds selectable
Up to 20 measurements per second for test frequencies ≧100 Hz
Accuracy
Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy depend on frequency, drive level and impedance
DC Bias Current (Option)
/D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage
Binning (Option)
10 bins with absolute and percentage limits
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability
Input Specification
Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz
Display
8.4" VGA (640 x 480) color TFT with touch panel
Measurement Connections
Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.
Printer
HP-PCL compatible graphics printing (local and network)
Centronics / parallel printer port, Epson compatible text/ticket printing (local)
Remote Trigger
Rear panel BNC with internal pull-up, operates on logic low or contact closure
GPIB Interface
External instrument control 24 pin IEEE 488 connector
USB Interface
Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant
VGA Interface
15-way D-type connector to drive an external monitor in addition to the internal screen
Network Interface
10/100-BASETX Ethernet controller
RJ45 connector
Keyboard Interface
Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in
Mouse Interface
Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected
Applications
​​Ideal for a broad spectrum of tasks including but not limited to:
-
Passive component design
-
Dielectric material characterization
-
High-frequency component evaluation
-
Quality control and archiving
-
Educational purposes
Key Features
-
High Precision Measurements: Characterize components with supreme accuracy across a wide frequency range from 20 MHz to 120 MHz, ensuring detailed analysis and quality assurance.
​
-
Versatile Measurement Options: Capacitance, inductance, and impedance measurements feature a basic accuracy of ±0.05%. Additional accuracy includes dissipation factor accuracy of ±0.0005 and quality factor accuracy of ±0.05%.
​
-
Graphical Sweep Capabilities: Perform graphical sweeps of two measured parameters across frequency, drive level, and DC bias, displayed on a large, clear color screen. Available display formats include series or parallel equivalent circuit models.
​
-
Advanced Analysis Tools: Equipped with Equivalent Circuit Analysis for modeling and curve fitting, alongside traditional LCR Meter mode for straightforward measurements. Features include resonance search and the option for polar and complex plots.
​
-
Ease of Use: A large TFT touch screen offers an intuitive user interface, simplifying complex measurements and data analysis.
​
-
Connectivity and Control: Fully programmable via GPIB and LAN interfaces, with options for keyboard and mouse controls. External monitor or projector connections are available for large screen displays, enhancing visibility in production or educational settings.
​
-
Data Management: Efficiently store and retrieve measurement and setup data through Ethernet or USB flash memory. Supports up to 20 local storage setups for each mode.
​
-
Safety Features: Integrated protection against charged capacitors to prevent damage and ensure longevity.
​
-
Additional Options: Variable AC drive levels up to 1Vrms or 20mArms, DC bias options ranging from 0 to +40V, and bin handling for quality control processes.
​​
Optional Features
-
DC Bias Variability: Choose between 0 to +40V DC bias voltage/current and a ±40V DC bias voltage option for comprehensive component evaluation.
​
-
Multi Measurement Mode: Enhance testing capabilities with additional measurement modes to suit various testing requirements.
​
-
Instrument Control Options: Enhance usability with optional keyboard and mouse control, catering to user preferences for instrument navigation and operation.
​​