The 6500B series of Precision Impedance Analyzers provide precise and fast
testing of components at frequencies up to 120 MHz. Basic measurement accuracy
is ±0.05% making the instruments the best in the class.
The accuracy and versatility makes the precision analyzers the ideal choice
for many different tasks and applications including passive component design,
dielectric material characterisation and manufacturing test.
Engineers need to evaluate component characteristics at high frequencies with
high levels of accuracy. The 65120B 120 MHz Precision Impedance Analyzer is
therefore ideal for many demanding tasks, combining accuracy and ease of use at
an affordable price. If a frequency range up to 120 MHz is not required then other
models are available. The 6505B 5MHz instrument is the entry level model in the
range.
|
| High measurement accuracy |
|
Capacitance, inductance and impedance basic accuracy is an excellent
±0.05%. Dissipation factor accuracy is ±0.0005 and the quality
factor accuracy is ±0.05%.
|
| Graphical sweep of components |
The 6500B series of Precision Impedance Analyzers are highly accurate
high frequency component analyzers with a host of useful features.
Graphical sweep of two measured parameters is available and displayed on
the clear, large, colour display. Swept parameters are frequency, drive
level and DC bias.
Display formats available include series or parallel equivalent circuit.
An Equivalent Circuit Anlysis function is available . This allows modelling
and curve fitting to various equivalent circuit models. Four types of three
component and a four component model are available. The instrument will
calculate the nearest equivalent circuit parameters for the measurement
traces and revise the results. Alternatively the component parameters may
be entered and the instrument will plot the frequency characteristics.
For single frequency measurements a meter mode is available.
|
 |
| Variable drive and bias levels |
AC drive levels up to 1V or 20mA can be selected to evaluate components
in realistic operating environments.
The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA
dc bias current while the /D2 option provides -40V to +40V dc bias voltage.
|
| External control |
|
The GPIB interface is used to control the instrument and read back measured
values for applications such as quality control or for archiving purposes.
An Ethernet interface similarly allows the instrument to be controlled and
to send out data - allowing it to be integrated into many test environments.
|
| Wide range of interfaces |
|
An external monitor or projector may be connected to the instrument.
The ability to provide a large screen display is invaluable in production
environments or for teaching and training.
Instrument control from both a keyboard and mouse is available. Any
keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to
provide an alternative method of instrument control and operation.
|
| Data storage and retrieval |
|
All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).
|
| Setup data |
|
Up to 20 instrument setups may be stored locally for each mode.
|
| Bin handling |
|
The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available
through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.
|
| Printer outputs |
|
Hard copy printouts can be obtained in a number of ways including direct to
an HP-PCL compatible graphics printer or Epson compatible text/ticket printer.
A networked HP-PCL compatible printer may also be used via Ethernet connection.
|
| Component connections |
Four front panel BNC connectors permit three or four terminal connections
with the screens at ground potential.
The 1J1011 component fixture, supplied as standard, ensures optimum performance
when measuring a wide range of components of leaded components and devices.
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.
|
| Protection against charged capacitors |
|
High precision measuring instruments can be damaged by charged capacitors which
can cause costly repairs and unacceptable downtime. All the models in the range
incorporate protection against charged capacitors.
|
| Comprehensive and precise component tests at higher frequencies |
|
The 6500B series capabilities are best summarised by “Comprehensive and precise
component tests at higher frequencies”. The instruments are the perfect solution
for those who have demanding component measurement needs.
|
| Technical Specifications: |
| Measurement Function |
Capacitance (C)
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø) |
| Frequency Range |
6505B 20Hz to 5MHz
6510B 20Hz to 10MHz
6515B 20Hz to 15MHz
6520B 20Hz to 20MHz
6530B 20Hz to 30MHz
6550B 20Hz to 50MHz
65120B 20Hz to 120MHz
Frequency step size 0.1 mHz
Accuracy of set frequency ±0.005"% |
| AC Drive Level |
10 mV or 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency) |
| Measurement Speeds |
4 speeds selectable
Up to 20 measurements per second for test frequencies ≥100 Hz |
| Accuracy |
Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy varies with frequency, drive level and measured impedance
|
| DC Bias Current (Option) |
/D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage |
| Binning (Option) |
10 bins with absolute and percentage limits
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability |
|
| General Data: |
|
Input Specification |
Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz
|
| Display |
8.4" VGA (650 x 480) color TFT with touch panel |
| Measurement Connections |
Four front panel BNC connectors permit two, three or four terminal connections with the
screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components
and devices.
|
| Printer |
HP-PCL compatible graphics printing (local and network)
Centronics / parallel printer port, Epson compatible text/ticket printing (local) |
| Remote Trigger |
Rear panel BNC with internal pull-up, operates on logic low or contact closure |
| GPIB Interface |
External instrument control 24 pin IEEE 488 connector |
| USB Interface |
Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant |
| VGA Interface |
15-way D-type connector to drive an external monitor in addition to the internal screen |
| Network Interface |
10/100-BASETX Ethernet controller
RJ45 connector |
| Keyboard Interface |
Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in |
| Mouse Interface |
Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected |
|